To the central content area

Work plan for 2017 fix pollution source audit control and the payment reminding and collection of air pollution fee

Absrtact
From March 7, 2017 to Dec 15, 2017, the results of the work are summarized as follows: (一) Promote licensing control system Till midterm this year, there has been 23 license applications filed: setting permit two times and the operation permit change five times respectively, with an average of the number of review days 3.05 days, which meets the statutory deadline (30 days). Secondly, through the license application, discussions were made with industry owners about emissions rationality, and counseling was used to reduce emissions permit, which contributed to VOCs reduction of 15.318 tons / year. As for the effective implementation of licensing system, the implementation of the license check is 32times, which shows the industry owners all comply with the regulations. (二) Stationary source controlled data inventory Till mid-term this year, we have completed a total of 160 controlled data inventory, which reached 100%. After the update, Chiayi City, as for stationary sources, there was a total of 345 controlled public and private places with an increase of 1 places more than the previous year. As the statistics of the filed stationary source database, it shows that part of the process pollution emissions, with particulate pollutants reaching 25.35tons / year, representing a reduction of 14.58 tons compared to that last year, sulfur oxides 19.53tons / year, representing a reduction of 0.21tons compared to that last year, nitrogen oxides 123.09 tons / year with an increase of 4.59 tons compared to that in the previous year, VOCs 140.20 tons / year, representing a reduction of 13.09tons compared to that last year, and carbon monoxide 30.22tons / year, representing an annual increase of 1.98 tons. (三) Air pollution fee collection and checking job In terms of air pollution imposed fee, we have completed Q4 in 2016 and Q2 in 2017 air pollution charges levied to review operations, with a total of air pollution managed public and private 83 premises with the average reporting rate 100%. Among them, Q1 in 2016, the makeup paying rate is 100% (NT$49,572). As for the check of air pollution fee, sulfur oxides and nitrogen oxides have been completed with 43 cases, and 43 cases of the volatile organic compounds. As for SOx / NOx, a total of 2 places have been found with errors in activity intensity; as for VOCs, 2 have been found with errors in activity intensity, it did not affect the air pollution fee, and also after counseling, the reporting and correction have been completed. After the completion of VOC solvent, has been done 1000 points times; the sampling tests and inspection results showed the leakage concentration 1 ~ 5ppm (highest proportion), accounting for 95 %, followed by 5 ~ 100ppm, accounting for 4%, while the 100 ~ 1000ppm, accounting for only 1%. The overall sampling tests results are all below the regulatory leakage defined value 1,000 ppm. Among 1000 point times sampling tests, The sampling tests and results meet the air pollution fee declaration circumstances. (四) Stationary sources regulatory compliance check As for the stationary pollutant compliance, the inspection check process was done on the public and private factories in our responsible area, including 5 times of station oil and gas leak test in the gas stations, among which 69times of shots among 65 are up to the standard with the average rate of 94% and all the ones not up to the standard have been improved completely. Determination of odor-functional has been followed up according to the law and been denounced the deadline for improvement. (五) Inspection job Till the mid-term this year, the completed cases have reached a total of 342. Among them, the inspection work had been done 117 times, mainly for the inspection of large pollution emissions and to meet Environmental Protection Agency emissions plans or subsidy measures, such as oil refinery industry, gas station industry, hotel industry, and the current inspection of each factory is in good condition. Among the 225 cases of inspection, the petition inspection accounted for 41% of all, which was the highest, followed by the detection inspection accounted for 26%. This year, the factories of the industry with more than two petitions in the same month were 1 factories. Besides, in 2016, there were four factories received petitions and at least one inspection was done every two months. After proactive inspections and protracted job counseling, the petition calls were not received. (六) Stationary sources advocacy conference In order to strengthen the implementation of public and private spaces licensing system and related regulations for cognitive stationary sources, and through advocacy conference, the communication between the industry and environmental protection agencies has improved. This year, one sessions of advocacy meetings had held, reaching 67%, which were air pollution control costs reporting and regulatory advocacy, road adopt job with evaluation highlights illustration meeting, stationary sources permit review, pollution control equipment explanation meeting, and the principles of advocacy briefing session with the attendance rate 51.80%、87.1%、67.5%.
Keyword
SOx, nitrogen oxides , volatile organic compounds , nitrogen oxides
Open
top