To the central content area

2018 Indoor Air Quality Management Project

Absrtact
The Taiwan Environmental Protection Administration (EPA) promulgated the Indoor Air Quality Management Act (IAQMA) in 2011, making Taiwan the second nation around the world after Korea to implement statutory regulations for indoor air quality (IAQ). To facilitate the implementation of the IAQMA, the EPA announced public and private premises that shall comply with the Act batch by batch. At present, the number of the first and second batches of announced premises in Taipei is 90 and 234, respectively. The amount of announced premises in Taipei is the highest in Taiwan as well as the most categories. To assist the announced and unannounced premises in Taipei to be more informed about IAQ management, this project has conducted matters related to inspection and examination, guidance, training, and promotion of regulation and IAQ voluntary management certificate. 220 premises were inspected for carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde (HCHO) by using portable devices. The sports and fitness centers, kindergarten, infant day care center, postpartum nursing center, parent-child center, office, and market were found to be the categories that the ventilation rates for local space may not meet the minimum requirements. Among them, the postpartum nursing center was one category that the ventilation rates for the whole space were estimated at relatively low levels. In addition, 60 premises were examined by standard reference methods. The levels of CO2 were found to exceed the legal threshold for 7 premises in which 3 announced premises have made improvements within a limited time period after guidenace. Furthermore, parallel sampling with the inspection instrument and reference method for total volatile organic compounds (TVOCs) and HCHO was performed in 5 premises where inspection results shows somewhat unusual affected by environmental interference. 20 premises received the on-site guidance to identify the symptoms and causes of poor IAQ, including pollutant source, air conditioning and ventilation system, maintenance and management. After guidance, constructive, economical, and problem solving approaches were suggested by the experts to correct poor IAQ problems. It is concluded that the ventilation and exhaust rates are critical for the sports and fitness centers, especially for underground small and medium-sized relevant premises. Besides, improvement of an index addressing both the ventilation conditions and risk of bacterial contamination for the diagnosis of IAQ management has been made. By using the radar chart of index, the performance of IAQ scope management was evaluated. The weak index can be therefore found for taking measures intended to provide IAQ that is acceptable. Finally, 3 workshops were held to train dedicated personnel for IAQ maintenance and management. The advantages of installing automatic equipment for continuous monitoring of IAQ were also promoted in the workshops. This year, 189 premised received the IAQ voluntary management certificates. Certificate breakdown shows that infant day care center, postpartum nursing center, and kindergarten, which are also sensitive groups, are the first three categories.
Keyword
indoor air quality
Open
top