To the central content area

Taitung County oil gas recovery at the gasoline station, volatile organic compounds and restaurant industry’s oil fumes control plan

Absrtact
Taitung County oil gas recovery at the gasoline station, volatile organic compounds and restaurant industry’s oil fumes control plan was started from Mar 3, 2006. In the main works includes to check and gorvern gasoline station’s VOCs sources, outside station’s VOCs pollution sources, measurements of emission pipes in stationary pollution sources or foul and noxious odors of periphral boundary testing, orther related promulgation, and restaurant industry’s oil fumes’check. This is as follows the achievement abstract explanation: 1. This year, we accepted 3 gasoline stations’ applications, including Fong-Gong station ( Stage 1), Dong-Ping station ( Stage 2 and 3), and Jin-Lun station ( Stage 2), they all examined pass. 2. This plan governed gasoline stations’ function tests and pollution control, we administered the A/L test and Leakage test to all gaoline stations in Taitung County, which totals to 36 stations. When fist examination, 36 stations all passed in Leakage test and A/L test ( Qualified rate is bigger than 70% ), but 12 stations’ oil guns qualified rate have not reached 100%. After epb dispatched official documents to request they to improve, they all passed 2nd test, and dealers all submited the test report after their improvements. 3. Tai-Fong station and Ruei-Fong station still not completed the establishment of oil gas recovery equipements before 2006 year’s end, so we ciunseled with them and traced their progresses, finally, they completed the establishments in Mar 1, 2006. Taitung County’s oil gas recovery system establishment rate has reached 100%. 50 gasoline stations we checked thoroughly this year average sales volumes are 7,829.13 KL/month. The work achievement renewed to the epa’s air pollutant management information system, the system automatic computation VOCs emission is about 145 tons/year. 4. In order to expand the propaganda effect, in promulgation aspect we printed 50 copies of the gasoline station oil gas recovery system operarion and maintenance and regulations guidance handbooks, 80 sheets of placards, the website published 1 news and provided 5 piece of news releases, asked the broadcasting station continuously to broadcast a week, every day three time intervals, and in places such as Taitung train station broadcasted the gasoline station guidance short film and the galloping-horse lantern. We also conducted the control regulations and the operation maintenance guidance explanation conference and the gasoline station control work ahievement and the self-criticism conference. 5. In order to carry on the epa long-term policy to refuel does not add fully and does not force to refuel, we proposed subscribes decides the gasoline station oil gas recovery work autonomy joint pledge the innovation method, and requested various gasoline stations industry and the respective staff signs together. Stops up to December 31, 2006, all 47 gasoline stations which needs to establish oil gas recovery system all signed the pledge and submited the epb to show to coordinate the policy determination. 6. Outside gasoline station, our check scalar of other VOCs emission sources is 30. To understand the present VOCs emission situation at population more crowded area, we checked 25 dry cleaning industry, 7 car care service industry, 2 gasseous fuel supply industry and 1 electricity generation industry ( 2 plant ), euqaled 36. Besides, we carried on 124 times of VOCs source ( including gasoline station ) patrols on own initiative to effectively hold actual VOCs emission condition. 7. This plan has already completed 3 times of examinations at Sep 9 and Nov 22, 2006, the objects of examination are Hong-Jin motor corporation ( odors, benzene and toluene of periphral boundary testing ) and Fong-Sin industry Co. (odors of periphral boundary testing ). The result of examinations was Hong-Jin motor corporation’s odor concentration exceede emission standard, we submited the report to epb for carring on accuse with the punishment. 8. This plan investigated 50 restaurants’ emission inventory and established the basic documents. The result of investigation was 5 restaurants did not install oil-water separator or any air pollution control devices, and most restaurants only installed baffles or screens. We helped 2 restaurant which have the risk of pollution to complete improvement of pollution control devices installation. Their improvement contained the installation of baffles, water screens, and oil-water separators in Ou-Siang chophouse, and the installation of baffles and packed tower in Hao-Tang business Inc. We also held a oil fumes control technology and improvement result conference for restaurant dealers, and arranged 2 improved restaurants’ scene visit.After the conference, we made the reference manual of regulations and pollution control technology, and we mailed it to dealers.
Keyword
gasoline station, pollution control, volatile organic compounds, restaurant industry’s oil fumes control, regulations
Open
top