英文摘要 |
The work team executes,” Project of collection, review and audit of air pollution fee of stationary sources in 2012-2013” for the environmental protection bureau of Kaohsiung City. The numbers of the cases, schedules and important results of this project are summarized and evaluated as follows for future reference.
1. Stationed staffs to manage the “ Kaohsiung Stationary Pollutant Source Air Pollution Control Fee audit Center ”
Starting from the commencement date of the contract, the project has stationed staffs to "Kaohsiung Stationary Pollutant Source Air Pollution Control Fee audit Center" to work on the collection of air pollution control fee, reporting and archiving, inspecting, final accounting audit.
2. Collect the air pollution control fee and help to finish the related administrative works including reporting, achieving, inspecting and final accounting audit from the EPA listed target companies.
This project files the air pollution control fee collection works from Q2 2012 to Q3 2013. There are total 1,035 companies on the list, and the results are:
(a) The collection percentage:
From Q2 2012 to Q3 2013, the collection percentage is 100%.
(b) The reporting mode
Refer to the Kaohsiung city’s latest report of Q3 2012, the numbers of the reports using the internet in Q1 2007 is 424 companies which is about 44% only (under the average rate of whole country). In Q3 2013, however, the numbers of reports using the internet have reached 1,025 companies, accounting for 99 % instead.
(c) The collection amounts of the air pollution control fee
In Kaohsiung City, from Q2 2012 to Q3 2013, the reported amounts of air pollution control fee from SOx and NOx are NT$ 740,510,000; the total amounts of air pollution control fee from VOCs is NT$ 481,890,000.
(d) Cases review and on-site inspection
i. The amounts of the air pollution control fee after review
Among the reviewed cases, from Q2 2012 to Q3 2013, the reported amounts of air pollution control fee are NT$1,198,760,000 but the amounts after review are NT$1,261,960,000, with a difference amounts in NT$ 58,960,000 needed to be further paid.
ii. The amounts of the pollutants
Among the reviewed cases, from Q2 2012 to Q4 2013, the reported amounts of air pollutants contain 58,187 tons of SOx, 90,924 tons of NOx and 21,222 tons of VOCs. The amounts after review are 58,048 tons of SOx, 74,151 tons of NOx and 21,664 tons of VOCs.
iii. The results of on-site inspection
During the execution of this project, we had finished for 769 times for the on-site air pollution inspections of factories.
3. Review the changes on the way of collecting the Stationary Source air pollution control fee in Kaohsiung City for future reference.
The pooled analysis plan for the "Air Pollution Fee system" significant doubt countermeasures and suggestions of both "Air pollution fee review and audit" currently incurred for reference.
|