英文摘要 |
The execution duration of this project is from March 1st, 2012 to February 28th, 2013. The final results of this project were separately introduced as the following:
1.Accepts permission application document 233 issues after due investigation 107 permits, rejects the application to be 73, other for in examination or test run.
2.The coordinate EPA third-level against system area promotion to the second-level against system area work, the air pollutant allowed that reduces the quantity to equal various air pollutant to reduce the total suspended particle pollutant 138 ton/years, the sulfur oxide compound 45 ton/years, the nitrogen oxide 106 ton/years and the volatile organic compounds 6.55 ton/years
3.There are 17 factories acquisition “Easy to cause air pollution material’s permit “, contains 16 the unburned coal use permit, the Formosa Plastics Group petrochemical gets extra the permit for refinery coke and the sulfur content surpasses 0.5% liquid fuel. In 2012, unburned coal total amount of use are 13.554 million tons.
4.The scene inspector general examines 150 (spot) time, including 51 regular examinations (spot) and 99 testing operations.
5.Total inspection of 100 factories and there are 40 factories not conforming to regulations with most of the reasons which the facilities are not in conformity with the approved content as stated in the permit.
6.There are 117 factories should report quantities of air pollutants emitted online ,the total reporting emissions quantities of air pollutants are 1,639 tons for particulate matter, 7,084 tons for sulfur oxides, 15,263 tons for nitrogen oxides, and 3,161 tons for volatile organic compounds. The percentage of declaration is 100%.
7.In 2012, total collection air pollution prevention fee are 198,990,370dollars. The percentage of declaration is 100%.
8.880 factories are under control in Yuilin County, total Stationary Pollution Source emissions quantities of air pollutants are 1906.445 tons for particulate matter, 7477.575 tons for sulfur oxides, 15327.139 tons for nitrogen oxides, and 3311.943 tons for volatile organic compounds.
9.467 inspections records are filing, 101 cases are fined NT$ 12.62 million.
10.117 gas stations are under control, completed 50 cases, 526 gasoline grease gun of the gas-to-oil ratio examination and the average qualified rate is 90.5%,2 stations is not qualified; Completes 15 cases of the inferior gas leakage examination and all are qualified.
|