環境資源報告成果查詢系統

一般性固定污染源揮發性有機空氣污染物排放管制規劃及評估計畫

中文摘要 本計畫係協助環保署進行一般行業別VOCs排放管制規劃及評估,今年度執行成果摘要如下:1.彙整一般行業別國內管道前端有效檢測結果277筆,據以研訂管道標準及減量效益;2.調查國內製程逸散情形共154廠次,403個製程;3.蒐集分析歐盟、美國之VOCs定義並建議以沸點作為揮發性有機物之認定依據;4.初擬以含VOCs原物料年許可用量50公噸以上者為第一階段之管制門檻; 5.依濃度及風量規模完成方塊式管道標準並進行「固定污染源空氣污染物排放標準」之研修;6.確認製程逸散管制規範並建議相關條文新增訂於「固定污染源揮發性有機物防制設施及監測設施管理辦法」(草案)中;7.針對317筆揮發性有機化學物質進行分析,將其依致癌性進行區分並分別評估其周界標準的適用性與建議研訂方式;8.預估管制標準推動將會有109,800公噸的減量效益;9.研擬永久性密閉式集氣隔間所需之成本估算、檢測方法分析彙整、收集效率認定方式彙整與清查作業表單設計等相關配套作業。
中文關鍵字 揮發性有機物,管道排放標準,容許逸散比率,排放管道與周界檢測方法

基本資訊

專案計畫編號 EPA-94-FA12-03-D070 經費年度 094 計畫經費 2500 千元
專案開始日期 2005/05/31 專案結束日期 2006/03/31 專案主持人 台灣大學 鄭福田
主辦單位 空保處 承辦人 執行單位 台灣大學 鄭福田

成果下載

類型 檔名 檔案大小 說明
期末報告 EPA-94-FA12-03-D070.pdf 20MB [期末報告]公開完整版

The survey and control of VOCs emission from stationary source

英文摘要 This plan helps the environmental protection administration to carry out the survey and control of VOCs emission from stationary source. The following summarize work that have been done in this year: (1) arranged and analyzed 277 effective stacks detected datum front of control equipments, and according these datum to draw up the stack standard and to calculate decrement benefit; (2) investigate into emission of current processes from 403 manufactures in 154 plants; (3) sort and analysis definitions issued by EU and USEPA, and proposed that a identified method of VOCs is based on it's boiling point.; (4) planed to regard including the stationary source who permitted consumption more than 50 tons of the original supplies of VOCs every year as the control threshold of the first stage for the first time; (5) according to stacks emission concentration and flow scale to establish the Square Stacks Standard and revised “Air pollution Emission Standard of Stationary Source”; (6) reviewed and checked the control standard of process emission and propose to add related rules in the draft of "Stationary Source’s VOCs Control Equipment and Monitor Management Method"(a draft); (7) distinguished 317 VOCs into carcinogen and non-carcinogen, and assessed the suitability of area concentration limit and provided the method to set up those limits, respectively; (8) estimated the standard is set in action that will have 109,800 tons of decrement benefits in advance; (9)established the related assignment, which is including estimated necessary cost of PTE, gathered and analyzed the related detection methods, collected the measuring methods of capture efficiency, and designed the related form ,etc.
英文關鍵字 volatile organic compound, emission standard of discharging pipes, fugitive emission limit, test method of stack gas/ambient air